Vertical screw water meter
Vertical rotor detachable water meter WS-50~2001 Use: Records the total amount of potable cold water flowing through the tap water pipeline. Features: Adopts a detachable core for easy maintenance. Magnetic dry structure ensures that the counter is clean and the display is clear. Low starting flow, high sensitivity. Internal adjustment structure effectively prevents unauthorized adjustment of the meter. Built-in stainless steel filter screen for easy user use. Bearing system made of special wear-resistant materials ensures a longer service life of the water meter. Can be equipped with a remote transmission counter. Note: The water meter performance indicators meet the ISO4064 international standard and GB/T7
Keyword:
Vertical screw water meter
Category:
Email:
Vertical screw water meter
Picture and Text Details
Vertical rotor detachable water meter
WS-50~200
1 Use: Record the total amount of potable cold water flowing through the tap water pipeline.
2 Features:
Adopts a detachable core for easy maintenance.
Magnetic dry structure ensures that the counter is clean and the display is clear.
Low starting flow, high sensitivity.
Internal adjustment structure effectively prevents unauthorized adjustment of the meter.
Built-in stainless steel filter screen for easy user operation.
Bearing system made of special wear-resistant materials ensures a longer service life of the water meter.
Can be equipped with a remote transmission counter.
Note: The water meter performance indicators conform to ISO4064 International standards and GB/T 778.1~3-2007 national standards.
3 Main parameters:
a 、Operating conditions: Water temperature ≤30 ℃ Water pressure ≤1.6Mpa
b 、Cold water meter operating temperature less than 50 ℃
Hot water meter operating temperature less than 90 ℃
c .Indicated error: At overload flow Q4 and the dividing flow Q2, the maximum error of the cold water meter is ±2%, and the maximum error between the dividing flow Q2 and the minimum flow Q1 (excluding the dividing flow Q2) is ±5%.
4 Installation dimensions and weight:
|
Nominal diameter DN mm |
Length mm |
Height mm |
Connecting flange |
Weight kg |
||
|
Flange outer diameter mm |
Bolt hole center circle diameter mm |
Number of bolts on one side- Hole diameter |
||||
|
50 |
280 |
220 |
165 |
125 |
4-φ18 |
15 |
|
80 |
370 |
285 |
200 |
160 |
4-φ18 |
27 |
|
100 |
370 |
300 |
220 |
180 |
4-φ18 |
29 |
|
150 |
500 |
480 |
285 |
240 |
4-φ22 |
80 |
5 Main technical parameters:
|
Specifications Model |
Q3/Q1 |
Q2/Q1 |
Overload flow Q4 |
Common flow Q3 |
Dividing flow Q2 |
Minimum flow Q1 |
Starting flow |
Minimum Reading |
Maximum Reading |
|
m 3/h |
m 3 |
||||||||
|
WS-50 |
R200 |
1.6 |
50 |
40 |
0.32 |
0.2 |
0.05 |
0.0005 |
999999 |
|
6.3 |
1.25 |
||||||||
|
WS-80 |
|||||||||