Spiral semi-liquid sealed water meter
Rotary semi-liquid sealed water meter LXSY-15~501 Purpose: To record the total amount of potable cold water flowing through the tap water pipeline. Features: The dial of this water meter adopts special liquid encapsulation, and the pointer part is kept filled with water for a long time, so that the reading can be kept clear permanently. It has the characteristics of convenient reading, good anti-fouling performance and beautiful appearance, and is especially suitable for use in China. Main parameters: a. Service conditions: Water temperature ≤30℃, water pressure ≤1Mpa b. Indicated error: The maximum error of cold water meter between overload flow Q4 and dividing flow Q2 is ±2%, and the maximum error between dividing flow Q2 and minimum flow Q1 (excluding dividing flow Q2) is
Keyword:
Spiral semi-liquid sealed water meter
Category:
Email:
Spiral semi-liquid sealed water meter
Picture and Text Details
Rotary semi-liquid sealed water meter
LXSY-15~50
1 Purpose: Record the total amount of potable cold water flowing through the tap water pipeline.
2 Features: The dial of this water meter adopts special liquid encapsulation, and the pointer part is kept full of water for a long time, so the reading can be kept clear permanently. It has the characteristics of convenient reading, good anti-fouling performance and beautiful appearance, and is especially suitable for use in China.
3 Main parameters:
a .Operating conditions: Water temperature ≤ 30 ℃ Water pressure ≤ 1Mpa
b .Indicated error: At overload flow Q4 and boundary flow Q2 the maximum error of cold water meter is ± 2% ,boundary flow Q2 and minimum flow Q1 between (excluding boundary flow Q2 ) maximum error ± 5%
Note:
a 、 The performance indicators of the water meter meet ISO4064 international standards and GB/T 778.1 ~ 3-2007 national standards.
b 、 LXSY-15~25 Plastic shell water meters and high-sensitivity water meters are optional.
4 Installation dimensions and weight:
|
Nominal diameter (mm ) |
Length |
Width |
Height |
Connecting thread |
|||||||
|
mm |
|||||||||||
|
L |
L1 |
B |
H |
d |
D |
||||||
|
a |
b |
c |
|||||||||
|
Recumbent type |
15 |
259 |
165 |
99 |
112 |
117 |
126 |
R1/2 |
G3/4B |
||
|
20 |
299 |
195 |
99 |
113 |
118 |
132 |
R3/4 |
G1B |
|||
|
25 |
345 |
225 |
103 |
120 |
125 |
|
R1 |
G11/4B |
|||
|
32 |
354 |
230 |
103 |
120 |
125 |
|
R11 /4 |
G11 /2B |
|||
|
40 |
373 |
245 |
103 |
154 |
129 |
|
R11 /2 |
G2B |
|||
|
50 |
454 |
300 |
124 |
174 |
179 |
|
R2 |
G21 /2B |
|||
Note :a is C type, E type, height of small liquid sealed meter b is dry type, liquid sealed meter height c is high shell meter height
5 Main technical parameters:
|
Nominal diameter (mm) |
Q3/Q1 |
|